Recent jobs
What people called us about, what we found and what we did.

Kitchen circuit tripping every evening
Thrushcote, (example job)
- The problem
- The kitchen sockets tripped most evenings around teatime, but never when we tested them in the morning.
- What we found
- Moisture inside an outdoor socket on the same circuit. It only tripped once the evening dew settled and the kettle went on.
- What we did
- Replaced the outdoor socket with a weatherproof one, resealed the cable entry and tested the whole circuit.
- Paperwork
- Minor Works Certificate

1970s fuse box replaced before a kitchen refit
Wendlow, (example job)
- The problem
- The owners were about to fit a new kitchen and their old fuse box had rewireable fuses and no RCD protection.
- What we found
- Two circuits had low insulation readings because of damaged cable behind the old kitchen units.
- What we did
- Repaired the damaged cable, fitted a new consumer unit with RCBOs and surge protection, and added a dedicated oven circuit.
- Paperwork
- Electrical Installation Certificate
Safety report for a rented terrace
Kestlebury, (example job)
- The problem
- A landlord needed a new report before a tenancy started the following week.
- What we found
- One C2 (a missing earth on a bathroom light) and two C3 recommendations.
- What we did
- Fixed the missing earth the same day with the landlord's agreement, then issued a satisfactory report.
- Paperwork
- Electrical Installation Condition Report